Converting fuel and other primary energy into electricity accounted for about 95% of US electricity system energy losses in 2025, according to an Energy Information Administration analysis released on 25 November. The agency puts the energy input at about 34 quadrillion British thermal units and electricity sold to end users at about 14 quadrillion. The gap is close to three fifths of the measured input. The analysis locates most of that gap at the generation stage, where thermal plants release heat as they turn their energy input into electrical output.
The scale can be checked against the agency's published tables. The Electric Power Annual lists 2025 US sales at just under 4.08 trillion kilowatt-hours. Expressing one kilowatt-hour as 3,412 British thermal units puts those sales at roughly 14 quadrillion British thermal units. A separate EIA energy flow chart likewise shows sales taking up about two fifths of the recorded input. These figures bring power and fuel quantities into the same unit so that the fuel entering the system can be compared with the electricity leaving it.
The comparison behind the numbers
A generator's heat rate measures the input used to produce one kilowatt-hour. A higher number means the generator uses more energy to produce that unit of electricity. EIA illustrates the difference with the American coal fleet, for which it cites an average input of about 10,077 British thermal units for each kilowatt-hour. Dividing the electrical output in the same units by that input gives an implied efficiency of roughly 34% for that example. The figure is a fleet average. The rate at a particular unit can vary with the equipment, fuel and operating conditions.
Engineering calculations make a separate allowance for the energy that disappears between the plant and the customer. The ASHRAE standard for high-performance buildings, for example, lists plant heat rates and delivery efficiency as separate factors when estimating how much source energy lies behind a metered unit. That distinction matters when comparing the potential of generation upgrades and network upgrades. One changes how much energy a plant takes in per kilowatt-hour. The other changes how much of its electrical output reaches the load.
What changes as the generation mix shifts
Changes in the national generation mix alter the balance even without a change in the performance of every plant. The federal analysis points to the long shift away from heavy reliance on coal and toward a mix that includes natural gas and renewables. Combined-cycle gas units can use heat from the gas turbine exhaust to produce additional electricity. A system using a greater share of those units can use less fuel for the same output than it would with a less efficient set of generators, depending on when the plants actually run.
The figures also reflect how the agency counts different resources. For wind and photovoltaic solar, the electricity produced is what enters the energy balance. The calculation omits the wind energy passing through the site or the sunlight reaching the panels. So a change in the mix may change the national loss share by changing the kinds of energy that enter the calculation. The balance tells a reader how the measured power system uses energy. It cannot be used by itself to rank the physical efficiency of a turbine, a solar panel and a steam plant.
Where network upgrades fit
Grid losses still matter to a utility trying to meet local demand. The federal analysis puts the 2025 transmission and distribution loss portion at less than one quadrillion British thermal units. Lower losses on a busy network can reduce the amount that generators must supply for the same delivery. The national average offers context, while investment decisions need information about particular lines, transformers and demand. This is why it matters to keep track of the losses during conversion and those during delivery when deciding where an efficiency project could have the greatest effect.